Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Millipore Milli-Q Advantage A10 Ultrapure Water Purification System

Fully Tested & Warrantied*
Brand : Millipore
Product Code : SKU 5654J WATER

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Millipore Milli-Q Advantage A10 Ultrapure Water Purification System with Q-POD Dispenser – Refurbished

The Millipore Milli-Q Advantage A10 Ultrapure Water Purification System is a high-performance laboratory water polishing system designed to produce Type 1 ultrapure water for sensitive analytical, pharmaceutical, biotechnology, and life science applications. Featuring a Q-POD remote dispensing station, integrated A10 total organic carbon (TOC) monitoring, advanced ion-exchange purification, and ultraviolet photo-oxidation, the Milli-Q Advantage A10 delivers precise control over laboratory water quality and dispensing.

Designed to operate with an existing source of prepurified water, the Milli-Q Advantage A10 produces ultrapure water with a resistivity of up to 18.2 MΩ·cm at 25°C and total organic carbon levels of 5 ppb or less under specified operating conditions. Its Q-POD dispenser provides adjustable flow rates from 50 to 2,000 mL/min, allowing researchers to dispense small volumes into analytical vessels or larger quantities for reagent preparation.

The system incorporates an integrated A10 TOC monitor, which measures organic contamination and provides valuable information about purification performance. Combined with electronic water-quality monitoring, programmable volumetric dispensing, and compatible application-specific final filters, the Milli-Q Advantage A10 provides a flexible solution for laboratories requiring high-purity water.

This Millipore Milli-Q Advantage A10, catalog number Z00Q0V0T0 and American Instrument Exchange inventory number 5654J, is used and refurbished. It includes the Q-POD dispensing configuration and is backed by AIE's 90-day warranty.

New purification filters and cartridges are not included. Customers must purchase the appropriate replacement consumables separately before placing the system into service.

Key Features

  • Millipore Milli-Q Advantage A10 ultrapure water purification system

  • Produces Type 1 ultrapure laboratory water from prepurified feedwater

  • Water resistivity up to 18.2 MΩ·cm at 25°C

  • Total organic carbon specification of 5 ppb or less under specified conditions

  • Integrated A10 TOC monitor with measurement range of 1–999 ppb

  • Q-POD remote dispensing station

  • Adjustable manual dispensing flow from 50–2,000 mL/min

  • Programmable volumetric dispensing from 100 mL to 60 L

  • Approximately 1% volumetric dispensing accuracy over the specified range

  • Ultraviolet photo-oxidation for organic contaminant reduction

  • Q-Gard and Quantum purification cartridge compatibility

  • Electronic resistivity, temperature, and TOC monitoring

  • Graphic display with system status and maintenance information

  • Compatible with optional Millipak and BioPak final polishing accessories

  • Compact main purification unit with flexible installation options

  • Suitable for sensitive analytical and life science applications

  • Refurbished and tested by American Instrument Exchange

  • 90-day warranty included

  • New purification filters and cartridges not included

Overview

The Milli-Q Advantage A10 is designed for laboratories that require a reliable source of ultrapure water beyond the quality typically supplied by reverse-osmosis or conventional deionization systems.

The instrument uses prepurified feedwater and applies additional purification technologies to reduce ionic and organic contamination.

The main purification module can be installed on a bench, beneath laboratory casework, or on a suitable wall mounting arrangement. The Q-POD dispenser is positioned separately, allowing ultrapure water to be collected directly at the point of use.

This arrangement helps laboratories conserve bench space while providing convenient access to high-quality water for daily research activities.

The integrated A10 TOC monitor distinguishes the Advantage A10 from more basic ultrapure water systems by providing direct information about organic contamination in the product water.

Common Applications

The Millipore Milli-Q Advantage A10 is used for high-performance liquid chromatography, analytical chemistry, mass spectrometry sample preparation, spectroscopy, reagent and buffer preparation, pharmaceutical research, molecular biology, biotechnology, and laboratory quality-control procedures.

It is also suitable for preparing ultrapure water used in sensitive analytical instruments, subject to the specific water-quality requirements of the application.

When equipped with appropriate final purification accessories, the system can support applications requiring additional control of bacteria, endotoxins, nucleases, or particulates.

Key Specifications

Specification Details
Manufacturer Millipore / Merck Millipore
Model Milli-Q Advantage A10
Catalog Number Z00Q0V0T0
AIE Inventory Number 5654J
Equipment Type Type 1 Ultrapure Water Purification System
Feedwater Requirement Prepurified Water
Compatible Feedwater Elix, RiOs, Distilled, or DI Water Meeting Specifications
Maximum Feedwater Conductivity Less Than 100 µS/cm
Maximum Feedwater TOC Less Than 50 ppb
Product Water Resistivity 18.2 MΩ·cm at 25°C
Product Water Conductivity Approximately 0.055 µS/cm at 25°C
Product Water TOC ≤5 ppb Under Specified Conditions
A10 TOC Monitor Range 1–999 ppb
Manual Dispensing Flow 50–2,000 mL/min
Automatic Dispensing 100 mL to 60 L
Automatic Volume Increments 250 mL to 5 L in 250 mL Steps; 5–60 L in 1 L Steps
Volumetric Dispensing Accuracy Approximately 1%, 250 mL to 60 L
Dispensing Repeatability CV Less Than 1%, 250 mL to 60 L
Dispenser Q-POD Remote Dispensing Station
Purification Technologies Ion Exchange, UV Photo-Oxidation, Final Polishing
UV Treatment 185 nm Photo-Oxidation
Main System Dimensions 13.07"W × 14.17"D × 19.56"H
Q-POD Dimensions 9.05" Diameter × 23.5"H
Main System Dry Weight Approximately 32 lb
Q-POD Dry Weight Approximately 11 lb
Electrical Supply 100–230V, 50/60Hz Manufacturer Range
Feedwater Temperature 5–35°C
Feedwater Pressure 0–0.3 Bar; Regulator Required Above 0.3 Bar
Data Connection Ethernet RJ45 on Main Unit
New Purification Filters Not Included
New Purification Cartridges Not Included
Condition Used / Refurbished
Warranty 90 Days

Specifications are based on Millipore manufacturer documentation and American Instrument Exchange product information. Published water-quality values assume suitable feedwater, functioning purification components, and appropriate final filters. Actual performance must be verified after installation of replacement consumables.

Ideal Laboratory Types

The Milli-Q Advantage A10 is particularly well suited to pharmaceutical research laboratories, biotechnology facilities, analytical chemistry departments, molecular biology laboratories, academic research institutions, environmental testing laboratories, and industrial quality-control facilities.

Its combination of high-resistivity water, TOC monitoring, and controlled dispensing is especially useful for laboratories that prepare analytical standards, chromatography solvents, and sensitive research reagents.

Type 1 Ultrapure Water Production

The Milli-Q Advantage A10 is designed to produce Type 1 ultrapure water with a resistivity of 18.2 MΩ·cm at 25°C.

High resistivity indicates extremely low concentrations of dissolved ionic contaminants, making this water suitable for many demanding laboratory procedures.

The system combines ion-exchange purification with ultraviolet treatment and compatible final polishing accessories to reduce impurities that may interfere with analytical measurements.

Unlike systems that produce reverse-osmosis water directly from tap water, the Advantage A10 is a final polishing system. It requires an existing supply of purified water that meets the manufacturer's feedwater specifications.

Integrated A10 Total Organic Carbon Monitoring

One of the defining features of the Milli-Q Advantage A10 is its integrated TOC monitor.

Total organic carbon is an important indicator of organic contamination in laboratory water.

Organic impurities can interfere with chromatography, spectroscopy, mass spectrometry, and other sensitive analytical procedures.

The A10 monitor measures TOC over a range of approximately 1–999 ppb and allows users to evaluate the organic purity of the product water.

The manufacturer's specified TOC performance is 5 ppb or less when the system is equipped with suitable purification cartridges and receives appropriately purified feedwater.

The monitor supports water-quality oversight but does not replace application-specific qualification or testing.

Q-POD Remote Dispensing System

The Milli-Q Advantage A10 includes a Q-POD remote dispensing station designed for convenient point-of-use access.

The Q-POD allows researchers to collect ultrapure water without working directly at the main purification module.

Its ergonomic dispensing control provides adjustable flow rates from 50 mL/min to 2 L/min.

Lower flow rates are useful when filling small analytical vessels, while higher flow rates support routine reagent preparation and filling larger containers.

The dispenser can accommodate different vessel sizes and offers precise control over the volume delivered.

The remote configuration also allows the main purification module to be installed away from the primary work area.

Programmable Volumetric Dispensing

The Q-POD dispenser provides automatic volumetric dispensing for applications requiring repeatable water quantities.

The system supports programmed delivery from 100 mL to 60 L.

For volumes between 250 mL and 5 L, users can select increments of 250 mL. From 5 L to 60 L, the system supports 1-liter increments.

The manufacturer specifies approximately 1% volumetric dispensing accuracy for quantities between 250 mL and 60 L.

This functionality is useful for preparing buffers, analytical solutions, mobile phases, and other laboratory reagents.

Ultraviolet Photo-Oxidation

The Milli-Q Advantage A10 incorporates ultraviolet treatment to help reduce organic contamination in the water purification pathway.

The 185 nm UV wavelength supports photo-oxidation of certain organic molecules, contributing to low TOC levels.

The UV system operates in conjunction with the purification cartridges to achieve the manufacturer's water-quality specifications.

UV treatment is particularly valuable for analytical applications where trace organic contamination may affect experimental results.

The condition and service life of the installed UV lamp should be evaluated during refurbishment and commissioning.

Purification Cartridge Technology

The Milli-Q Advantage A10 uses compatible Q-Gard purification packs and Quantum polishing cartridges.

These consumables work together to remove residual ionic and organic contaminants from prepurified feedwater.

The appropriate cartridge configuration depends on the feedwater source and intended application.

The manufacturer's low-TOC performance specifications are based on specified cartridge combinations, including the Q-Gard T1 pack and Quantum TEX cartridge.

Replacement cartridges must be selected according to the installed system configuration and current manufacturer compatibility guidance.

Optional Final Polishing for Specialized Applications

The Milli-Q Advantage A10 supports application-specific point-of-use filtration accessories.

Millipak final filters are used to help reduce particulates and microbial contamination.

BioPak ultrafilters provide additional purification for applications requiring particularly low levels of endotoxins and nucleases.

With the appropriate final polisher installed, the manufacturer publishes specifications for bacteria, endotoxins, RNases, and DNases.

These specialized specifications should not be assumed achievable with the base purification system alone.

Laboratories should select the appropriate final filter according to their experimental requirements.

Electronic Water Quality Monitoring

The Milli-Q Advantage A10 provides electronic monitoring of important system parameters.

The main display presents operating status, maintenance information, water-quality measurements, and system alerts.

Resistivity measurements help users assess ionic purity, while the A10 TOC monitor provides additional information about organic contamination.

The system also includes user-access controls for selected settings and functions.

These features support routine monitoring and help laboratories identify when maintenance or consumable replacement may be necessary.

Feedwater Requirements and Installation

The Milli-Q Advantage A10 must be connected to a suitable source of prepurified water.

Compatible feedwater sources include Millipore Elix or RiOs systems, distilled water, or deionized water meeting the manufacturer's specifications.

The manufacturer specifies feedwater conductivity below 100 µS/cm and TOC below 50 ppb.

This is an important distinction from the Millipore Direct-Q series, which incorporates reverse osmosis for direct connection to suitable potable tap water.

The Advantage A10 is not intended to replace a complete tap-water pretreatment system.

Installation also requires suitable electrical service, appropriate tubing and fittings, and adequate clearance for maintenance.

Purification Filters and Cartridges – Not Included

This refurbished Milli-Q Advantage A10 is sold without new purification filters or cartridges.

Customers are responsible for obtaining and installing the correct replacement consumables before using the system.

Depending on the configuration, these may include a Q-Gard purification pack, Quantum polishing cartridge, and a compatible Q-POD final filter.

The UV lamp, tubing, and other maintenance components should also be evaluated according to their condition and service history.

Because new purification consumables are not included, the system's final water-quality performance must be verified after installation and commissioning.

Refurbishment and Testing by American Instrument Exchange

American Instrument Exchange supplies inspected and refurbished laboratory water purification equipment.

For the Milli-Q Advantage A10, relevant functional testing includes evaluating the electronic controls, display, internal pump, valves, resistivity monitoring, TOC monitoring, and Q-POD dispensing functions.

The main purification module, water connections, tubing, dispenser controls, and electrical components should also be inspected.

Because new filters and cartridges are not included, final ultrapure water performance should be confirmed after the buyer installs suitable consumables.

Customers requiring documented water-quality testing, TOC verification, or confirmation of particular accessories should discuss those requirements with AIE before purchase.

The refurbished Milli-Q Advantage A10 includes a 90-day warranty.

Shipping and Installation

The Milli-Q Advantage A10 main purification module measures approximately 13.07 inches wide, 14.17 inches deep, and 19.56 inches high.

The Q-POD dispenser measures approximately 9.05 inches in diameter and 23.5 inches high.

The compact design allows the purification module to be installed in several laboratory configurations while keeping the dispensing station conveniently positioned.

The system should be packaged carefully to protect its electronic controls, dispenser, tubing, and internal purification components.

Following installation, laboratories should install the appropriate consumables, complete the manufacturer's startup and flushing procedures, and verify water quality before critical use.

Related Equipment

Laboratories using the Milli-Q Advantage A10 may also require Millipore Direct-Q water purification systems, laboratory glassware washers, laboratory autoclaves, and analytical balances.

American Instrument Exchange supplies used and refurbished laboratory water purification systems and related equipment for pharmaceutical, biotechnology, academic, analytical, and industrial laboratories.

Millipore Milli-Q Advantage A10 FAQs

What is the Milli-Q Advantage A10 used for?

The Milli-Q Advantage A10 produces Type 1 ultrapure water for sensitive analytical testing, chromatography, reagent preparation, pharmaceutical research, and other laboratory applications.

What water quality does the Advantage A10 produce?

With appropriate consumables and suitable feedwater, the system produces water with resistivity up to 18.2 MΩ·cm at 25°C and TOC of 5 ppb or less.

Can the Milli-Q Advantage A10 operate directly from tap water?

No. The Advantage A10 requires prepurified feedwater, such as appropriately treated Elix, RiOs, distilled, or deionized water.

What is the Q-POD dispenser?

The Q-POD is a remote dispensing station that allows users to collect ultrapure water at adjustable flow rates and dispense programmed volumes.

What is the maximum dispensing rate?

The Q-POD supports manual dispensing rates up to approximately 2 liters per minute.

What does the A10 TOC monitor measure?

The A10 monitor measures total organic carbon, an indicator of organic contamination in ultrapure water.

Are new filters and cartridges included?

No. New purification filters and cartridges are not included with AIE inventory unit 5654J and must be purchased separately.

Can the system produce nuclease-free or endotoxin-controlled water?

It can support these applications when equipped with appropriate final polishing accessories, such as a compatible BioPak ultrafilter, and when the resulting water quality is verified.

What is the difference between the Milli-Q Advantage A10 and Direct-Q 3UV-R?

The Advantage A10 is an ultrapure water polishing system that requires prepurified feedwater and includes integrated TOC monitoring. The Direct-Q 3UV-R incorporates reverse osmosis and can produce both Type 3 and Type 1 water from suitable potable tap water.

Does the system include a remote dispenser?

Yes. AIE's listing identifies a Milli-Q Advantage A10 with a Q-POD dispensing station.

Does the refurbished Milli-Q Advantage A10 include a warranty?

Yes. American Instrument Exchange provides a 90-day warranty on this refurbished water purification system.

Testing Procedures for Used and Refurbished Laboratory Equipment

Ensure Accuracy, Safety, and Dependable Performance Across Applications

At American Instrument Exchange, all used and refurbished laboratory equipment undergoes a rigorous, multi-point testing protocol to ensure optimal performance, operational safety, and long-term reliability. Whether the equipment is destined for research, diagnostics, quality control, or production environments, our thorough inspection and testing process is designed to meet the highest standards of laboratory excellence.

Why Testing Used Lab Equipment Is Essential

Before any refurbished laboratory equipment is returned to service, it must be carefully tested to verify:

• Functional integrity and operational performance
• Setpoint accuracy and repeatability (where applicable)
• User interface responsiveness and control features

Proper testing reduces the risk of equipment failure, measurement inaccuracies, or user hazards—helping to ensure consistent results in clinical, academic, biotech, and industrial labs.

Our standardized lab equipment testing procedures are tailored to each equipment type, ensuring every unit meets manufacturer specifications and industry benchmarks.

Key Testing Procedures for Refurbished and Used Laboratory Equipment

1. Initial Visual Inspection

• Examine equipment housing for signs of wear, corrosion, or damage
• Check ports, power cords, and exterior components for tampering or deterioration
• Verify that internal and external parts (racks, shelves, connectors, accessories) are present and undamaged

2. Functional Startup and Operational Testing

• Power on the equipment and verify startup diagnostics
• Confirm functionality of displays, buttons, switches, and control panels
• Run basic functions to confirm proper response and behavior under standard operating conditions

3. Testing and Performance Verification

• Test internal sensors or control systems using industry-standard tools
• Perform operational tests to validate accuracy and consistency
• Verify key performance specifications such as temperature control, timing, speed, or measurement outputs, depending on equipment type

4. Mechanical and Electrical System Testing

• Evaluate motors, pumps, fans, or other moving parts for smooth operation
• Inspect and test wiring, relays, fuses, and circuit boards for safety and reliability
• Test power delivery and grounding compliance

5. Safety and Compliance Checks

• Ensure equipment is grounded and insulated to meet laboratory safety standards
• Test alarms, interlocks, emergency stops, or safety shutdown systems if applicable

6. Final Quality Assurance and Documentation

• Perform extended runtime testing
• Document operational logs, testing results, and any repairs or adjustments made
• Complete a final inspection, thorough cleaning, and packaging for delivery

Trusted Quality from American Instrument Exchange

With over 50 years of experience in laboratory equipment refurbishment, American Instrument Exchange is committed to delivering certified, lab-ready instruments backed by expert testing. Our testing protocols ensure that each piece of equipment—regardless of type—is safe, accurate, and dependable from day one.

Whether you're equipping a startup lab or expanding a high-throughput facility, you can count on our refurbished laboratory equipment to perform with precision and reliability.

Refurbishment Protocol for Used Laboratory Equipment from American Instrument Exchange

At American Instrument Exchange, every piece of used laboratory equipment we offer undergoes a multi-step refurbishment process. Whether it's an analytical balance, centrifuge, freezer, oven, or any other essential lab instrument, our goal is to restore each unit to peak performance—ensuring accuracy, safety, and long-term reliability in scientific, clinical, industrial, and academic environments.

Why Choose Refurbished Lab Equipment from American Instrument Exchange?

• Thoroughly tested for performance, precision, and safety
• Backed by a warranty
• A cost-effective alternative to new equipment
• Environmentally sustainable through equipment reuse and waste reduction
• Serviced by expert technicians with decades of laboratory equipment experience

Step-by-Step Refurbishment Protocol

Every instrument and system refurbished at American Instrument Exchange follows a detailed, industry-aligned process:

1. Initial Intake & Inspection

• Complete visual and structural inspection for cosmetic damage, wear, or corrosion
• Mechanical assessment of hinges, seals, fasteners, motors, and moving parts
• Missing components and damaged items are documented for repair or replacement

2. Cleaning and Decontamination

• Full internal and external cleaning using non-abrasive, lab-safe solutions
• Removal of biological, chemical, or particulate contamination
• Disassembly and cleaning of removable parts such as trays, shelves, and filters

3. Mechanical and Electrical Repair

• Replacement or repair of worn or broken mechanical parts
• Evaluation and servicing of control panels, sensors, switches, and displays
• Testing and repair of electrical wiring, fuses, circuit boards, and power supplies

4. Functional System Testing

• Assessment of all major functions specific to the equipment type (e.g., speed, temperature, force, weight, timing)
• Operation of control interfaces, programming menus, and digital displays
• Verification of stabilization time, responsiveness, and user input reliability

5. Testing and Performance Verification

• Testing of internal sensors, controllers, and measurement systems using certified tools
• Multi-point testing to ensure repeatability, accuracy, and performance consistency
• Confirmation of user-defined setpoints, timing sequences, or programmable cycles

6. Safety and Compliance Checks

• Testing of safety interlocks, alarms, and over-limit protection systems (as applicable)
• Electrical safety inspections, including grounding and insulation verification

7. Final Quality Assurance and Documentation

• Full operational testing under simulated lab conditions
• Completion of performance benchmarks, testing  results, and repair logs
• Final cleaning and visual inspection

Trust the Experts at American Instrument Exchange

With over 50 years of experience in the laboratory equipment industry, American Instrument Exchange is a trusted leader in high-quality refurbished lab instruments. Our refurbishment protocols ensure that every piece of equipment we sell is lab-ready—offering the precision, performance, and durability your team can count on.

Whether you’re outfitting a new lab or expanding an existing operation, choose American Instrument Exchange for tested, warrantied, and cost-effective laboratory equipment.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.