Mettler Toledo XPE205T Analytical Balance – Used & Refurbished

The Mettler Toledo XPE205T Analytical Balance is a high-resolution laboratory balance designed for demanding quantitative applications where conventional 0.1 mg analytical balance readability may not provide sufficient resolution. With a 220 g maximum capacity and 0.01 mg (10 µg) readability, the XPE205T is well suited for pharmaceutical research, analytical chemistry, formulation, standards preparation, quality control, gravimetric analysis, and other procedures requiring highly precise measurement of small mass differences.

This Mettler Toledo XPE205T is available used and refurbished from American Instrument Exchange and includes a Mettler Toledo RS-P42 printer. Each balance is inspected, cleaned, calibrated, and tested for weighing accuracy and repeatability before shipment and includes a 90-day warranty from American Instrument Exchange.

Key Features

  • 220 g maximum weighing capacity

  • 0.01 mg / 10 µg readability

  • Typical repeatability of 0.007 mg / 7 µg

  • Typical USP minimum weight of approximately 14 mg

  • ±0.1 mg linearity

  • Approximately 2.5-second settling time

  • proFACT Advanced automatic internal adjustment

  • SmartGrid weighing pan helps reduce turbulence inside the weighing chamber

  • StaticDetect technology identifies potentially problematic electrostatic charges

  • MinWeigh supports minimum sample-weight control

  • LevelGuide alerts users when the balance requires leveling

  • StatusLight provides immediate visual balance-status information

  • Infrared sensors support hands-free operation

  • Detachable color touchscreen terminal

  • Tool-free removable draft shield components for easier cleaning

  • LabX compatible

  • Mettler Toledo RS-P42 printer included

  • Used, refurbished, calibrated, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Mettler Toledo XPE205T occupies an interesting position between a conventional analytical balance and a semi-micro balance. Its 10 µg readability is ten times finer than the 0.1 mg readability commonly associated with standard analytical balances, making it capable of detecting extremely small changes in sample mass while retaining a useful 220 g capacity.

This combination makes the XPE205T particularly attractive for laboratories that need greater resolution for small samples but do not necessarily require the 1 µg readability of a dedicated microbalance.

Mettler Toledo designed the XPE platform around more than the weighing cell itself. The balance incorporates technologies intended to identify and reduce common sources of measurement uncertainty, including static electricity, improper leveling, environmental disturbances, and weighing below established minimum sample weights.

StaticDetect can identify electrostatic charges that may compromise weighing results. LevelGuide helps ensure proper balance setup, while StatusLight provides immediate visual feedback regarding instrument status. MinWeigh can alert users when sample quantities fall below established minimum-weight limits.

The result is a sophisticated analytical weighing system designed not simply to display mass, but to help laboratories recognize conditions that could compromise the reliability of that measurement.

Common Applications

The XPE205T is particularly well suited for applications involving small samples, highly precise quantitative preparation, and procedures where measurement uncertainty must be carefully controlled.

Pharmaceutical and biotechnology laboratories can use the XPE205T for active ingredient weighing, standards preparation, formulation research, sample preparation, reference-material preparation, quality control, and other quantitative procedures involving relatively small quantities.

Analytical and chemical laboratories may use the balance for gravimetric analysis, solution and standard preparation, differential weighing, density determination, filter weighing, reagent preparation, and other high-resolution measurements.

Environmental, materials science, academic research, and industrial quality-control laboratories may also benefit from the XPE205T when small changes in sample mass must be detected reliably.

The included RS-P42 printer can be particularly useful for laboratories that require immediate hard-copy documentation of weighing results as part of their routine workflow.

Ideal Laboratory Types

The Mettler Toledo XPE205T is a strong choice for pharmaceutical, biotechnology, analytical chemistry, environmental testing, materials science, academic research, formulation, manufacturing, and quality-control laboratories.

It is particularly appropriate for laboratories that have outgrown the resolution of a conventional 0.1 mg analytical balance but do not necessarily need to move all the way to a dedicated microbalance.

With 10 µg readability and 220 g capacity, the XPE205T provides considerably greater weighing flexibility than many microbalances while still delivering resolution appropriate for demanding small-sample analytical work.

High-Resolution Analytical Weighing Performance

The defining characteristic of the XPE205T is its 0.01 mg, or 10 µg, readability. This allows the balance to resolve mass changes one-tenth the size detectable by a conventional 0.1 mg analytical balance.

Mettler Toledo specifies typical repeatability of approximately 7 µg, linearity of ±0.1 mg, and a settling time of approximately 2.5 seconds.

This combination of high resolution and relatively fast stabilization makes the XPE205T particularly useful for repetitive analytical procedures where both measurement quality and laboratory throughput matter.

The balance's SmartGrid weighing pan is designed to reduce turbulence within the weighing chamber, helping the weighing system stabilize more quickly. The enclosed draft shield further protects high-resolution measurements from air currents and other environmental disturbances.

For laboratories comparing analytical, semi-micro, and microbalances, the XPE205T offers an attractive compromise: substantially greater resolution than a standard analytical balance while retaining a comparatively generous 220 g weighing capacity.

Minimum Sample Weight & USP Applications

Minimum sample weight becomes increasingly important as laboratory balances are used for smaller and smaller quantities.

Mettler Toledo specifies a typical USP minimum weight of approximately 14 mg for the XPE205 under stated conditions. The manufacturer also lists an automated typical USP minimum weight of approximately 10 mg.

These figures illustrate why a high-resolution balance such as the XPE205T can be valuable for pharmaceutical and other regulated laboratories. A conventional analytical balance may not provide adequate measurement uncertainty when extremely small quantities are being weighed.

The XPE platform's MinWeigh functionality can help operators recognize when the net sample weight falls below an established weighing tolerance.

Actual minimum weight depends on installed balance performance, environmental conditions, repeatability, measurement uncertainty requirements, and laboratory procedures. Laboratories performing regulated measurements should therefore determine and document minimum weight according to their own qualification procedures and applicable quality system.

Controlling Drafts, Vibration & Static

At 10 µg readability, environmental conditions become a major part of accurate weighing. Air currents, bench vibration, temperature gradients, static electricity, improper leveling, and even operator technique can influence measurement results.

The XPE205T incorporates several technologies designed specifically to address these problems.

Its enclosed draft shield protects the weighing chamber from room air currents, while the SmartGrid weighing pan reduces turbulence around the sample. LevelGuide warns the operator if the balance is not correctly leveled, and StatusLight provides immediate visual feedback regarding balance readiness.

Static electricity can be particularly problematic when weighing powders, plastic containers, filters, glassware, and other materials capable of accumulating electrical charge. The XPE platform's StaticDetect technology is designed to recognize electrostatic charges that may produce measurement errors.

For high-resolution work, the balance should still be installed on a rigid, vibration-resistant surface away from HVAC vents, frequently opened doors, direct sunlight, centrifuges, shakers, refrigerators, compressors, and other potential sources of disturbance.

An anti-vibration balance table can be particularly beneficial when the XPE205T is used near the lower end of its weighing range.

Calibration & Internal Adjustment

The XPE205T incorporates Mettler Toledo's proFACT Advanced automatic internal adjustment system, helping maintain weighing performance as laboratory conditions change.

Automatic internal adjustment can compensate for temperature-related influences and reduces reliance on manually initiated adjustment procedures during routine use.

For critical or regulated measurements, internal adjustment should not be considered a replacement for appropriate external verification. Laboratories operating under GLP, GMP, USP, or internal quality systems may require scheduled testing using traceable weights along with documented calibration and qualification procedures.

American Instrument Exchange evaluates refurbished balances using appropriate test weights and verifies critical weighing characteristics before shipment.

Data Management, LabX & the Included RS-P42 Printer

The XPE205T is designed for laboratories where weighing results may need to become part of a documented analytical workflow.

Compatibility with Mettler Toledo LabX software allows the balance to be incorporated into systems supporting SOP guidance, electronic data handling, calculations, storage, and reporting. This can reduce manual transcription and improve consistency across standardized weighing procedures.

This particular American Instrument Exchange unit also includes a Mettler Toledo RS-P42 printer, providing a convenient method for producing hard-copy records of weighing results.

For laboratories operating under formal quality systems, the combination of electronic data-management capability and local printing provides flexibility in how weighing information is recorded and incorporated into laboratory documentation.

Key Specifications

Specification Mettler Toledo XPE205T
Balance Type High-Resolution Analytical Balance
Maximum Capacity 220 g
Readability 0.01 mg / 10 µg
Typical Repeatability 0.007 mg / 7 µg
Typical USP Minimum Weight 14 mg
Automated Typical USP Minimum Weight 10 mg
Linearity ±0.1 mg
Settling Time Approx. 2.5 seconds
Adjustment Internal / proFACT Advanced
Weighing Pan 73 × 78 mm
Weighing Pan Technology SmartGrid
Draft Protection Enclosed draft shield
Static Detection StaticDetect
Minimum Weight Assistance MinWeigh
Level Monitoring LevelGuide
Balance Status StatusLight
Display Detachable color touchscreen
Hands-Free Operation Infrared sensors
Overall Dimensions 263 mm W × 487 mm D × 322 mm H
Software Compatibility LabX
Legal for Trade No
Included Accessory Mettler Toledo RS-P42 printer

Choosing Between an Analytical, Semi-Micro & Microbalance

Selecting the right high-resolution balance requires considering both the smallest sample being weighed and the maximum capacity required.

A conventional analytical balance commonly provides 0.1 mg readability and is sufficient for many routine quantitative laboratory procedures. A microbalance may provide 1 µg readability but typically has a much smaller maximum capacity and is considerably more sensitive to environmental conditions.

The XPE205T falls between these categories. Its 10 µg readability provides ten times finer resolution than a conventional 0.1 mg analytical balance while retaining a full 220 g capacity.

That makes the XPE205T particularly useful for laboratories that occasionally or routinely work with small sample quantities but still need enough capacity for conventional weighing vessels, containers, and larger analytical samples.

For procedures requiring true microgram-level readability down to 1 µg, a dedicated microbalance such as the Mettler Toledo XPE26 may be more appropriate. For routine work where 0.1 mg readability is sufficient, a conventional analytical balance may offer a more economical solution.

Refurbishment & Performance Testing

Every used Mettler Toledo XPE205T sold by American Instrument Exchange is inspected, cleaned, refurbished as necessary, calibrated, and tested before shipment.

High-resolution analytical balances require more than a basic power-on test. Our technicians use appropriate test weights to evaluate critical performance characteristics including accuracy, repeatability, linearity, corner-load tolerances, stability, and reduced span at or near full capacity.

The proFACT internal adjustment system, touchscreen, draft shield, weighing pan, leveling system, display, controls, sensors, and other installed features are also inspected and tested for proper operation.

The weighing chamber and removable components are thoroughly cleaned prior to shipment. The XPE draft shield is designed for easy disassembly, helping simplify ongoing cleaning once the balance is installed in the customer's laboratory.

Each refurbished XPE205T includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation Considerations

A balance capable of resolving 10 µg changes in mass requires careful transportation and installation. American Instrument Exchange securely prepares the XPE205T for shipment to protect the weighing cell, SmartGrid pan, draft shield, touchscreen terminal, and included accessories.

Once received, the balance should be installed on a rigid, level, vibration-resistant work surface in an area with stable temperature and minimal airflow.

The balance should be allowed to acclimate to its new environment before final adjustment, verification, and critical weighing procedures are performed.

For demanding applications, laboratories should consider a dedicated balance bench or anti-vibration table and avoid locating the instrument near HVAC vents, doors, centrifuges, shakers, refrigeration compressors, or other sources of vibration and temperature fluctuations.

Related Laboratory Equipment

American Instrument Exchange maintains an extensive inventory of used and refurbished laboratory balances, including analytical balances, semi-micro balances, microbalances, and precision balances for applications ranging from routine sample preparation to high-resolution quantitative analysis.

Labs developing complete analytical or sample-preparation workflows can also source centrifuges, water baths, incubators, laboratory refrigerators, laboratory freezers, and other refurbished laboratory equipment from American Instrument Exchange.

Mettler Toledo XPE205T Analytical Balance FAQs

What is the capacity of the Mettler Toledo XPE205T?

The XPE205T has a maximum weighing capacity of 220 g, providing substantially more capacity than many dedicated microbalances while retaining extremely fine readability.

What is the readability of the XPE205T?

The XPE205T provides 0.01 mg, or 10 µg, readability. This is ten times finer than the 0.1 mg readability commonly found on conventional analytical balances.

What is the typical repeatability of the XPE205T?

Mettler Toledo specifies typical repeatability of approximately 0.007 mg, or 7 µg, under appropriate operating conditions.

What is the typical USP minimum weight of the XPE205T?

Mettler Toledo specifies a typical USP minimum weight of approximately 14 mg under stated conditions, with an automated typical USP minimum weight of approximately 10 mg. Actual minimum weight should be established according to installed balance performance and the laboratory's measurement requirements.

Is the XPE205T an analytical balance or a microbalance?

The XPE205T is a high-resolution analytical balance. Its 10 µg readability places it between a conventional 0.1 mg analytical balance and a 1 µg microbalance, making it particularly useful for laboratories requiring greater analytical resolution without sacrificing 220 g capacity.

How does StaticDetect help improve weighing accuracy?

Electrostatic charge on samples or containers can exert forces that cause unstable or inaccurate weighing results. StaticDetect identifies potentially significant electrostatic charges, allowing the operator to address the problem before accepting the measurement.

Does the XPE205T have automatic internal calibration?

Yes. The XPE205T incorporates proFACT Advanced automatic internal adjustment, helping maintain weighing performance as environmental conditions change. Regulated laboratories may still require documented external verification and calibration.

Does this XPE205T include a printer?

Yes. This American Instrument Exchange XPE205T includes a Mettler Toledo RS-P42 printer, providing a convenient method for producing hard-copy weighing records.

Is the XPE205T compatible with LabX?

Yes. The XPE platform is compatible with Mettler Toledo LabX laboratory software, allowing SOP guidance, automated data handling, calculations, storage, reporting, and other advanced workflow capabilities when appropriately configured.

Why purchase a refurbished Mettler Toledo XPE205T?

A refurbished XPE205T provides access to sophisticated Mettler Toledo high-resolution weighing technology—including 10 µg readability, StaticDetect, proFACT Advanced, SmartGrid, MinWeigh, StatusLight, LabX compatibility, and an included RS-P42 printer—without the acquisition cost associated with comparable new high-resolution analytical balances. American Instrument Exchange tests, cleans, calibrates, and refurbishes the balance before shipment and provides a 90-day warranty.

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.