Skip to content
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details
LAB EQUIPMENT REPAIRS, INCLUDING ULTRALOW FREEZERS, FRIDGES, CENTRIFUGES AND MORE - Click here for details

Mettler Toledo MS32001L Precision Balance

Fully Tested & Warrantied*
Product Code : SKU 0678C BALANCE
Date In: 6/3/2025

Shipping

All products ship from our 30,000 sq. ft. Haverhill, MA warehouse

Mettler Toledo MS32001L Precision Balance – Used & Refurbished

The Mettler Toledo MS32001L Precision Balance is a rugged, high-capacity laboratory balance designed for accurate weighing of large samples, bulk materials, heavy containers, and kilogram-scale formulations. With a maximum capacity of 32.2 kg and 0.1 g readability, the MS32001L provides substantially more weighing capacity than conventional benchtop balances while retaining the precision required for laboratory, quality-control, formulation, and production-support applications.

Available used and refurbished from American Instrument Exchange, the Mettler Toledo MS32001L offers proven MonoBloc weighing technology, FACT automatic internal adjustment, a large stainless steel weighing platform, and durable construction at a significantly lower acquisition cost than comparable new equipment. Each balance is inspected, cleaned, calibrated, and tested for weighing performance before shipment and includes a 90-day warranty from American Instrument Exchange.

Key Features

  • 32.2 kg / 32,200 g maximum weighing capacity

  • 100 mg / 0.1 g readability

  • Typical repeatability of approximately 0.07 g

  • Typical USP minimum weight of approximately 140 g

  • FACT automatic internal adjustment

  • Proven MonoBloc weighing technology

  • Robust chemical-resistant aluminum housing

  • Large 245 × 351 mm stainless steel weighing pan

  • Approximately 2-second settling time

  • High-contrast backlit display with large digits

  • Three programmable SmartKeys for frequently used functions

  • SmartTrac graphical weighing-range indicator

  • Integrated USB and RS232 connectivity

  • Below-balance weighing capability

  • Multiple built-in weighing applications

  • Used, refurbished, calibrated, and tested by American Instrument Exchange

  • 90-day warranty included

Overview

The Mettler Toledo MS32001L is designed for laboratories that need to weigh quantities far beyond the capacity of conventional analytical and benchtop precision balances. Its 32.2 kg capacity accommodates large containers, bulk samples, formulation vessels, raw materials, and heavy laboratory components while maintaining 0.1 g readability throughout its weighing range.

This combination makes the MS32001L particularly useful when container tare weight becomes a significant part of the measurement. Instead of dividing materials among smaller containers simply to stay within the capacity of a lower-range balance, users can place larger bottles, vessels, carboys, or other containers directly on the MS32001L and retain substantial usable weighing capacity.

Mettler Toledo's MonoBloc weighing technology provides a durable, repeatable weighing system, while FACT automatic internal adjustment helps maintain performance as environmental conditions change.

The weighing cell is housed inside a robust chemical-resistant aluminum enclosure designed for demanding laboratory environments. A large stainless steel weighing platform provides ample room for oversized items, while the straightforward display and programmable SmartKeys make the balance well suited for frequent routine use.

Common Applications

The Mettler Toledo MS32001L is particularly well suited for laboratory procedures involving large samples, bulk materials, heavy containers, and kilogram-scale formulations.

Pharmaceutical and biotechnology laboratories can use the balance for media and buffer preparation, bulk reagent preparation, formulation, scale-up procedures, component weighing, production support, and quality control. The large capacity allows ingredients to be weighed directly into bottles, carboys, vessels, and other preparation containers.

Chemical laboratories can use the MS32001L for compound preparation, formulation development, percentage weighing, batching, totaling, check weighing, and bulk sample preparation.

Food and beverage, cosmetics, materials science, manufacturing, and industrial laboratories can also use the balance for ingredient weighing, recipe preparation, raw-material testing, inventory procedures, formulation, and other applications where kilogram-scale quantities must be measured with reliable 0.1 g resolution.

Ideal Laboratory Types

The MS32001L is a strong choice for pharmaceutical, biotechnology, chemical, food and beverage, cosmetics, materials science, manufacturing, industrial research, academic, and quality-control laboratories.

It is particularly valuable in facilities where laboratory-scale development overlaps with pilot-scale or production-support work. Its 32.2 kg capacity makes it possible to handle quantities that would overwhelm most conventional laboratory balances without requiring laboratories to move immediately to a less precise industrial platform scale.

The durable metal housing and large stainless steel pan also make the MS32001L appropriate for busy laboratories where weighing equipment is used frequently and must accommodate larger containers and heavier samples.

High-Capacity Precision Weighing Performance

The Mettler Toledo MS32001L provides 0.1 g readability across a 32.2 kg weighing range, allowing relatively small differences in mass to be measured while working with loads weighing tens of kilograms.

Mettler Toledo specifies typical repeatability of approximately 0.07 g and typical linearity deviation of approximately 0.06 g, with linearity specified at ±0.3 g. Settling time is approximately 2 seconds.

The relationship between capacity and readability is the primary advantage of this balance. A laboratory can place a heavy vessel on the weighing pan, tare its mass, and still retain substantial capacity for the actual formulation or sample.

This can simplify media preparation, buffer preparation, formulation, batching, and other procedures where dividing ingredients into multiple smaller weighing operations would increase handling time and create additional opportunities for error.

Minimum Sample Weight & USP Applications

Maximum capacity and readability do not by themselves determine whether a balance is suitable for a particular quantitative procedure. Laboratories working under USP requirements should also consider the minimum sample weight required to achieve an acceptable level of measurement uncertainty.

Mettler Toledo specifies a typical USP minimum weight of approximately 140 g for the MS32001L under stated conditions. Typical minimum weight at U=1%, k=2 is approximately 14 g.

These values illustrate an important consideration when selecting a high-capacity precision balance. Although the MS32001L can display changes as small as 0.1 g, it is primarily designed for substantially larger samples rather than small-scale analytical measurements.

Actual minimum weight depends on the installed balance's repeatability, environmental conditions, calibration status, measurement uncertainty requirements, and laboratory procedures. Laboratories performing regulated or validated measurements should establish minimum weight according to their own qualification procedures and applicable quality system.

Heavy Samples, Large Containers & Overload Protection

Handling large samples introduces practical challenges that are less significant with smaller analytical balances. Containers may be bulky, loads may not always be placed perfectly in the center of the pan, and accidental overloads can potentially damage sensitive weighing components.

The MS32001L was designed specifically with these conditions in mind. Its large 245 × 351 mm stainless steel platform provides substantially more usable surface area than a conventional benchtop balance.

The MonoBloc weighing system incorporates overload protection to help safeguard the balance against accidental excessive loading. This is particularly valuable in laboratories where carboys, bottles, vessels, bulk materials, and other heavy items are routinely moved around the weighing station.

Overload protection should not be interpreted as additional weighing capacity—the balance's maximum operating capacity remains 32.2 kg—but it provides an additional level of protection for the weighing mechanism during everyday use.

Controlling Vibration & Environmental Influences

The MS32001L is considerably less sensitive to minor environmental disturbances than a microbalance or analytical balance, but vibration, temperature changes, unstable work surfaces, strong airflow, and improper leveling can still affect measurement performance.

This becomes particularly important when large or unevenly distributed loads are placed on the weighing platform.

For best results, the MS32001L should be installed on a rigid, level, vibration-resistant surface capable of safely supporting both the balance and its maximum anticipated load.

Placement immediately adjacent to centrifuges, shakers, compressors, frequently opened doors, or other significant vibration sources should be avoided whenever possible.

The chemical-resistant aluminum housing and stainless steel weighing surface also simplify routine cleaning, an important consideration for formulation and preparation areas where powders, liquids, and raw materials may be handled around the balance.

Calibration & Internal Adjustment

The MS32001L incorporates Mettler Toledo's FACT fully automatic internal adjustment system.

FACT can initiate internal adjustment based on time and temperature conditions, helping compensate for environmental changes that might otherwise affect weighing performance. This reduces reliance on manually initiated adjustment procedures during routine laboratory operation.

Automatic internal adjustment does not eliminate the need for appropriate performance verification. Laboratories operating under GLP, GMP, USP, or internal quality systems may still require scheduled testing with traceable external weights along with documented calibration and qualification procedures.

American Instrument Exchange tests refurbished balances using appropriate calibration weights and evaluates performance at multiple points across the weighing range before shipment.

Routine Weighing Applications & Connectivity

The MS32001L is designed to handle more than simple weight determination. Built-in applications support common laboratory and production procedures including piece counting, percent weighing, dynamic weighing, check weighing, formulation, totaling, statistics, and factor weighing.

Three programmable SmartKeys allow frequently used applications or functions to be assigned to dedicated keys, reducing the number of menu steps required during repetitive workflows.

SmartTrac provides a graphical representation of the amount of weighing capacity currently being used, which can be particularly helpful when adding ingredients sequentially during formulation or batching.

The balance also provides USB and RS232 connectivity, allowing compatible printers, computers, scanners, and other peripherals to be incorporated into the weighing workflow. Electronic transfer of results can reduce manual transcription and simplify documentation.

Key Specifications

Specification Mettler Toledo MS32001L
Balance Type High-Capacity Precision Balance
Maximum Capacity 32.2 kg / 32,200 g
Readability 100 mg / 0.1 g
Typical Repeatability 0.07 g
Typical USP Minimum Weight 140 g
Typical Minimum Weight (U=1%, k=2) 14 g
Linearity ±0.3 g
Typical Linearity Deviation 0.06 g
Settling Time Approx. 2 seconds
Adjustment Internal / automatic FACT
Weighing Pan 245 × 351 mm
Display High-contrast backlit LCD
Overall Dimensions 363 mm W × 346 mm D × 118 mm H
Weighing Technology MonoBloc
Housing Chemical-resistant die-cast aluminum
Connectivity USB-A and RS232
SmartKeys 3 programmable keys
Below-Balance Weighing Yes
Legal for Trade No, standard configuration

Choosing Between the MS32001L and an Analytical Balance

The MS32001L and a conventional analytical balance solve very different weighing problems.

An analytical balance commonly provides 0.1 mg readability and is designed for small samples requiring very high measurement resolution. Maximum capacity is typically measured in hundreds of grams, and the balance normally uses an enclosed draft shield to protect sensitive measurements from environmental disturbances.

The MS32001L instead provides 32.2 kg capacity with 0.1 g readability. It sacrifices sub-milligram sensitivity in exchange for dramatically greater capacity, a large open weighing surface, and easier handling of bulky samples and containers.

For laboratories preparing large formulations, buffers, media, bulk reagents, or other kilogram-scale quantities, the MS32001L is therefore considerably more practical.

Many laboratories can benefit from having both instrument types available: an analytical or semi-micro balance for small quantities and a high-capacity precision balance such as the MS32001L for bulk preparation and larger samples.

MS32001L vs. MS32001L/A03

American Instrument Exchange may stock more than one version of the Mettler Toledo MS32001L, including the MS32001L/A03.

Both models share the core advantages of the MS platform, including 32.2 kg capacity, 0.1 g displayed readability, MonoBloc weighing technology, a large stainless steel weighing pan, and automatic internal adjustment.

The important distinction is that approved variants such as the MS32001L/A03 are designed for applications requiring a legally approved weighing configuration, subject to the specific certification and local regulatory requirements of the individual balance.

The standard MS32001L is intended primarily for laboratory, research, formulation, quality-control, and internal process weighing where legal-for-trade approval is not required.

For most research laboratories, this distinction will have little effect on everyday weighing performance. Laboratories requiring a certified or legal-for-trade instrument should confirm the exact approval status of the individual balance before purchase.

Refurbishment & Performance Testing

Every used Mettler Toledo MS32001L sold by American Instrument Exchange is inspected, cleaned, refurbished as necessary, calibrated, and tested before shipment.

Testing goes beyond simply confirming that the balance powers on and displays a weight. Our technicians evaluate critical weighing characteristics including accuracy, repeatability, linearity, corner-load tolerances, and reduced span at or near full capacity using appropriate calibration weights.

The MonoBloc weighing system is evaluated for consistent response and stability. FACT internal adjustment, the display, SmartKeys, weighing platform, controls, interfaces, and other installed functions are also checked for proper operation.

The balance is thoroughly cleaned and receives a final inspection before shipment.

Each refurbished MS32001L includes a 90-day warranty from American Instrument Exchange.

Shipping & Installation Considerations

The MS32001L is a precision measuring instrument and should be carefully packaged and handled during transportation. American Instrument Exchange securely prepares the balance to protect its MonoBloc weighing system, stainless steel platform, display, and other components.

Because the balance can accommodate more than 32 kg, particular attention should be given to the installation surface. The bench or table must be rigid, stable, level, and capable of safely supporting the balance plus the anticipated sample and container weight.

After installation, the balance should be allowed to acclimate to the laboratory environment before final adjustment and critical weighing procedures are performed.

For laboratories operating under regulated quality systems, installation should be followed by appropriate calibration, verification, or qualification according to internal procedures.

Related Laboratory Equipment

American Instrument Exchange maintains an extensive inventory of used and refurbished laboratory balances, including analytical balances, semi-micro balances, microbalances, and precision balances for applications ranging from routine sample preparation to high-resolution quantitative analysis.

Labs developing complete analytical or sample-preparation workflows can also source centrifuges, water baths, incubators, laboratory refrigerators, laboratory freezers, and other refurbished laboratory equipment from American Instrument Exchange.

Mettler Toledo MS32001L Precision Balance FAQs

What is the maximum capacity of the Mettler Toledo MS32001L?

The MS32001L has a maximum weighing capacity of 32.2 kg, or 32,200 g, making it suitable for large containers, bulk samples, formulations, and kilogram-scale laboratory preparation.

What is the readability of the MS32001L?

The Mettler Toledo MS32001L provides 100 mg, or 0.1 g, readability across its weighing range.

What is the typical repeatability of the MS32001L?

Mettler Toledo specifies typical repeatability of approximately 0.07 g under appropriate operating conditions.

What is the typical USP minimum weight of the MS32001L?

Mettler Toledo specifies a typical USP minimum weight of approximately 140 g under stated conditions. Actual minimum weight should be established according to the individual balance's installed performance, environmental conditions, measurement uncertainty, and applicable laboratory procedures.

Does the MS32001L have automatic internal calibration?

Yes. The MS32001L incorporates Mettler Toledo's FACT automatic internal adjustment system, which can initiate adjustment based on time and temperature conditions. Laboratories operating under regulated quality systems may still require documented external verification and calibration.

What is the difference between the MS32001L and MS32001L/A03?

Both models provide approximately 32.2 kg capacity and 0.1 g displayed readability. The A03 is an approved configuration intended for applications where legal-for-trade certification may be required, while the standard MS32001L is generally intended for laboratory and internal process weighing. Certification status should always be confirmed for the individual instrument.

Is the MS32001L suitable for buffer and media preparation?

Yes. Its combination of 32.2 kg capacity, 0.1 g readability, and a large 245 × 351 mm pan makes the MS32001L particularly useful for weighing ingredients directly into larger vessels during buffer, media, reagent, and formulation preparation.

Can the MS32001L be connected to a computer or printer?

Yes. The MS32001L provides USB and RS232 connectivity, allowing it to communicate with compatible computers, printers, scanners, and other laboratory peripherals.

What applications are built into the MS32001L?

Depending on configuration, the MS32001L supports applications including standard weighing, piece counting, percent weighing, dynamic weighing, check weighing, formulation, totaling, statistics, and factor weighing.

Why purchase a refurbished Mettler Toledo MS32001L?

A refurbished MS32001L provides laboratories with proven Mettler Toledo MonoBloc weighing technology, FACT automatic internal adjustment, 32.2 kg capacity, and robust laboratory construction without the acquisition cost associated with comparable new equipment. American Instrument Exchange tests, calibrates, cleans, and refurbishes each balance before shipment and provides a 90-day warranty.

Testing Procedures for Used and Refurbished Laboratory Balances

Ensure Precision, Repeatability, and Weighing Accuracy

Used and refurbished laboratory balances from American Instrument Exchange undergo thorough, multi-point testing to ensure accurate, reliable performance in scientific, industrial, and pharmaceutical settings. Each balance is carefully inspected, calibrated, and evaluated to meet the stringent standards required for analytical, precision, and micro weighing applications.

Why Testing Used Laboratory Balances Is Essential

Before a laboratory balance is placed back into service, it must be rigorously tested for:
• Weighing accuracy across full capacity range
• Repeatability and linearity
• Load cell and sensor functionality
• User interface and calibration system integrity

Comprehensive balance testing helps eliminate measurement errors and guarantees performance in high-precision environments such as R&D, formulation labs, and quality control facilities.

Our structured balance testing protocol ensures every refurbished unit delivers consistent results and trusted performance.

Key Testing Procedures for Refurbished and Used Laboratory Balances

1. Initial Visual Inspection

• Inspect housing, leveling feet, draft shield, and weighing pan for wear, cracks, or corrosion
• Check control panel, power cord, and buttons for damage or signs of tampering
• Confirm presence and condition of all required components (e.g., shields, adapters, trays)

2. Functional Startup and Interface Testing

• Power on the balance to verify display initialization and zeroing functionality
• Test user interface responsiveness, menu access, and programmable features
• Evaluate stabilization time and auto-tare functions

3. Calibration and Accuracy Testing

• Perform internal calibration (if equipped) and verify operation
• Use certified calibration weights to perform external calibration
• Check for accuracy at multiple weight points across the balance’s range

4. Repeatability, Linearity, and Corner Load Testing

• Conduct multiple weighings of identical test weights to confirm repeatability
• Test linearity by weighing at low, mid, and high points across the range
• Evaluate corner-load accuracy by placing test weights at different positions on the pan

5. Load Cell and Sensor Integrity Verification

• Test load cell response for consistency, drift, or hysteresis
• Verify sensor functionality and precision at sub-milligram levels (for analytical/microbalances)

6. Electrical Safety and Grounding Checks

• Inspect wiring and power components for safety and compliance
• Verify proper grounding and electrical insulation to meet lab equipment standards

7. Final Quality Assurance and Documentation

• Perform a full operational test under simulated lab conditions
• Record and document all calibration results and test metrics
• Final cleaning and inspection before shipping

Trusted Performance from American Instrument Exchange

All refurbished laboratory balances from American Instrument Exchange are tested and validated to deliver precision weighing performance from day one. Our expert technicians use industry-standard procedures to ensure each balance is lab-ready—whether used for sample prep, formulation, or high-precision research.

Repair and Refurbishment Protocol for Used Laboratory Balances

Precision Weighing Restored by American Instrument Exchange

At American Instrument Exchange, every used laboratory balance is subjected to a multi-step refurbishment protocol designed to restore precision and reliability with laboratory standards. Whether it’s an analytical balance, precision balance, or microbalance, we ensure each unit delivers consistent performance for scientific, pharmaceutical, and industrial applications.

Why Choose a Refurbished Laboratory Balance from American Instrument Exchange?

• Fully tested for accuracy, repeatability, and calibration stability
• Backed by a warranty
• Cost-effective alternative to purchasing new balances
• Environmentally responsible through expert refurbishment and reuse
• Refurbished by technicians with extensive experience in lab instrumentation

Step-by-Step Laboratory Balance Refurbishment Protocol

Every laboratory balance from American Instrument Exchange is professionally restored through a comprehensive, multi-point process:

1. Initial Intake & Inspection

• Exterior inspection for damage, corrosion, and wear on display, housing, and leveling feet
• Visual/manual check of weighing pan, draft shield, doors, and buttons
• Documentation of missing parts, error codes, or component issues

2. Cleaning and Decontamination

• Thorough cleaning of the weighing chamber, pan, and internal components using anti-static and non-abrasive cleaners
• Removal of dust, chemical residue, and particulate buildup
• Disinfection of all surfaces

3. Mechanical and Electronic Repairs

• Replacement/repair of worn components including pans, draft shields, and buttons
• Evaluation and repair of load cells, sensors, and electronic boards
• Inspection of power supply, internal wiring, and display screen functionality

4. Calibration and Accuracy Testing

• Internal calibration mechanisms are tested (if equipped)
• External calibration is performed using certified traceable weights
• Repeatability, linearity, and corner-load accuracy are verified

5. Functional Testing and Performance Validation

• Test of user interface, menu settings, and programmable functions
• Taring, zeroing, and stability response times are evaluated
• Load-bearing accuracy is tested across the unit’s full capacity range

6. Compliance and Safety Checks

• Electrical system testing for grounding and safe operation
• Verification of leveling system and anti-vibration performance

7. Final Quality Control and Documentation

• Final inspection and multi-point accuracy verification
• Complete operational test with weight logs and calibration reports
• Full cleaning and packaging for shipment

Trust the Experts at American Instrument Exchange

With over 50 years of experience in laboratory equipment, American Instrument Exchange is a trusted source for precision-refurbished laboratory balances. Our refurbishment protocol ensures each balance meets strict standards for accuracy and performance—ready to deliver dependable weighing results from day one.

Warranty Information

All used equipment sold by American Instrument Exchange is refurbished/reconditioned, tested to meet specifications, cleaned, and comes with a 90-day warranty from the date of shipment unless otherwise specified. New products include a warranty from the manufacturer. Your warranty is only valid if you have paid your invoice. If your invoice is over 30 days old, warranty work will not be performed until your invoice is paid in full.  American Instrument Exchange is not liable for any special or consequential damages that result from the use of, or the inability to use, the materials on this site or the performance of the products,

Exceptions include international sales and items that are agreed to be sold with a lesser warranty or items that are agreed to be sold “as is.”

Should there be visible shipping damage to packaging or concealed shipping damage to item(s) supplied, buyer must communicate such damage to the delivering entity or carrier upon receipt first and to American Instrument the same day item is accepted / signed for. Failure to do so voids warranty. Customer decision to involve / procure third party or OEM service other than American Instrument or AIE assigned vendors to resolve in-warranty instrument failure or defect without first placing a service call to American Instrument voids warranty.

Return & Cancellation Policy

American Instrument Exchange will authorize the return of and issue a full refund for any equipment that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by AIE or a representative of AIE during the warranty period. Returns without prior authorization and an RMA number will not be accepted. 

Customers are responsible for proper packaging of the equipment and all included accessories. American Instrument will pay for insurance and shipping costs. Non-inventory items bought specifically to fill customer orders may possibly be returned, but on a case by case basis.

Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues may be subject to a Restocking/Cancellation Fee of 20% or more and responsible for shipping costs for both the delivery and return.

Ongoing and Extended Support Options

American Instrument Exchange is able to provide additional repair and support services outside the warranty terms for most products that sell.

For biosafety cabinets, clean benches, chemical fume hoods, and other clean air products our team at AIE Laboratory Services can provide certifications, repairs, decontaminations, and other services for customers throughout New England, and guidance and limited technical assistance for any customers in the US and Canada for new or refurbished biosafety cabinets purchased from American Instrument Exchange.

For all other products, the repair service team at American Instrument Exchange can provide both field and depot repair evaluations. We can easily schedule and coordinate the pick-up and transportation of your malfunctioning equipment. By offering hourly rates lower than most OEM service providers and eliminating travel time for technicians, we help reduce repair costs. Furthermore, our lab depot repair service minimizes or eliminates scheduling delays. Our experienced service technicians are qualified to restore your equipment to factory specifications.

Please contact our team at info@americaninstrument.com for more details.

FAQ

Does the equipment come with a warranty?

Yes, all equipment from American Instrument Exchange comes with a warranty.
Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer's specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.

How do you test and recondition the equipment?

Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality.
We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly.

How do products ship from American Instrument Exchange?

We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements.

Return and order cancellation policy

American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer's satisfaction during the warranty period. Customers who cancel orders after refurbishing has begun will be subject to a cancellation and restocking fee of between 20% and 40%.

Are discounts available for educational or non-profit institutions, or for bulk purchases?

Yes – call or email us today with a list of equipment you're looking for and we can potentially put together a quote that includes a discount.

How does your price matching policy work?

We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we'll do our best to match or beat the price.

Can I see the equipment in person before committing to a purchase?

Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.

1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.

Can I ship products that I purchased elsewhere to American Instrument for repair?

Yes – please see our repair services page for more information.