The Baker SterilGARD e3 SG404M biosafety cabinet is the most energy efficient biosafety cabinet available today. The newly redesigned airflow management system saves energy and improves both user comfort and safety. The energy saving features not only provide up to 60% increased energy efficiency when compared to similar biosafety cabinets. This also extends HEPA filter lifespan by up to 30%.
This SterilGARD SG404M comes with a fully adjustable, electronically controlled hydraulic stand.
4’ Baker SG404M – Specifications
Class II Type A2, 4’ wide (53” exterior, 46” work surface)
Includes new supply and exhaust HEPA filters
Includes hydraulic stand
90-day warranty
Click here to see the Baker SG404M on the American Instrument Exchange YouTube channel.
4’ Baker SG404M – Features
The Baker SterilGARD e3 SG404 also features the new trademarked ReadySAFE mode. A unique padded armrest allows the cabinet to continue operation and maintain A2 conditions with the viewscreen in the close position.
When the sash is lifted, the cabinet is instantly safe upon resuming standard operation. The versatile ReadySAFE mode is designed to be used during breaks (even extended breaks such as overnight) to maintain safe conditions and save energy.
The Baker e3 SG404 cabinet has audible and visual alarms to alert the operator of some unsafe conditions including power/processor fault alarm, viewscreen alarm, and double viewscreen position sensor fault alarm.
Each SG404 cabinet has one cable port located on the right sidewall. This provides a safe means of introducing power cables, vacuum aspiration tubing or other similar items into the work area. It is designed with flexible neoprene seals allowing multiple cables and/or tubing totaling up to 1 inch in diameter.
The operator controls and indicators are arranged in a single, easily cleaned membrane switch assembly on the front of the cabinet. There are push buttons for blower, fluorescent light, outlets, optional ultraviolet light and alarm mute.
The motor and blower are built as a single assembly and balanced to minimize vibration. The motor control automatically compensates for an increase in pressure drop across the filters without reducing the total air flow rate by more than 10%. The air flow capacity of the cabinet is measured by the ability to provide a nearly constant volume of air as the filter resistance to airflow increases.
Testing
This 4’ Baker SG404M is used and reconditioned. Our technicians test each biosafety cabinet to ensure that the controls and blower motor work properly. Unless otherwise specified all biosafety cabinets come with new HEPA filters installed by our technicians at our facility prior to shipment.
Our testing procedure includes all the elements of a biosafety cabinet certification in order to ensure that the unit will pass certification once it is at your site.
4’ Baker SG404M - Additional Specifications
Exterior dimensions (not including stand)
53.75”W x 30.5”D x 61.75”H
Interior work surface dimensions
46”W x 24.5”D x 27.5”H
Working sash height
12"
Weight (not including stand)
Approx 585 lbs
Electrical Requirements (call or email to confirm)
115V, 60Hz, 15 amp
Pictures
The photos above represent our equipment, which is currently stored in our warehouse. Since we often stock multiple units of each model, we may not feature photos of every unit. However, if you request, we will provide photos of your specific equipment after we test and clean it.
For inquiries about the Baker SterilGARD e3 SG404M 4' A2 Biosafety Cabinet, call us at 978-521-2221 or fill out the form on this page.
FAQ
Does the equipment come with a warranty?
Yes, all equipment from American Instrument Exchange comes with a warranty. Used/reconditioned/refurbished equipment is tested to make sure it operates to the manufacturer’s specifications and comes with a 90-day warranty (unless otherwise noted). New equipment comes with a warranty from the manufacturer.
How do you test and recondition the equipment?
Testing requirements vary across all the equipment categories we sell. Temperature controlled units are tested with NIST traceable probes and data loggers. Gaskets, external housing, glass, handles, controls and control screens are all thoroughly inspected for integrity and functionality. We test all equipment using the manufacturer's parameters and specifications to confirm that the unit operates properly. While we may not be able to test for specific analytical applications we do our best to simulate the conditions under which the equipment will be used in your lab. If you have particular testing requirements please let us know and we’ll work with you to make sure these are addressed during testing.
How do products ship from American Instrument Exchange?
We can ship products both nationally and internationally using a well-established network of transporters. Smaller items will ship via UPS. Larger equipment will be palletized and shipped either LTL or air-ride, depending on the specific equipment and/or delivery requirements. In many cases we can offer inside delivery. Customers are also welcome to make pick-up arrangements using their own preferred carrier.
All shipments are FOB Haverhill, MA. American Instrument Exchange will take reasonable steps to protect the equipment during shipment and the equipment will be fully insured. The customer will be charged for all shipping and handling charges, and fees incurred in the process of delivering the order.
For local customers in and around New England we can offer shipping and delivery using a local moving company trained by our staff to handle and deliver lab equipment. Our local movers can provide either standard dock-to-dock delivery or bring the equipment into your lab and set it in place.
Prior to signing the POD (Proof of Delivery), you are responsible for inspecting the goods for any damage. You MUST note any damage on the POD prior to letting the driver leave. This is to protect you, the receiver of the goods in the unlikely event of any damage. Once you sign the POD free and clear from damage, the goods are then deemed delivered in good order and no further claims would be applicable. This is the standard for all transportation so we want to protect you, our valued client.
Return and order cancellation policy
American Instrument Exchange will accept the return of any product that is not working as represented and could not be replaced or repaired to the customer’s satisfaction by American Instrument or a technician hired by/vetted by American Instrument Exchange’s during the warranty period. The customer will be responsible for proper packaging of the equipment and all included accessories.
Customers who cancel orders after refurbishing has begun or after delivery where there are no equipment performance issues will be subject to a cancellation and restocking fee of between 20% and 40% and responsible for the full total of the shipping & handling costs for both the delivery and the return of the equipment.
Are discounts available for educational or non-profit institutions, or for bulk purchases?
Yes – call or email us today with a list of equipment you’re looking for and we can potentially put together a quote that includes a discount.
How does your price matching policy work?
We strive to keep our pricing competitive and reasonable. If you find comparable items for sale at a lower price from other vendors please send us a link and or quote for the item and we’ll do our best to match or beat the price.
Can I see the equipment in person before committing to a purchase?
Customers are welcome to make an appointment to view equipment in our warehouse. Given our workload we may not be able to test or clean the equipment prior to your arrival if you have not committed to an order.
1023 Western Avenue is a working warehouse, not a showroom, and customers should dress appropriately and wear closed toe shoes.
Can I ship products that I purchased elsewhere to American Instrument for repair?
Yes – please see our repair services page for more information.